THERMOMETER - HYGROTHERMOMETER
Anti-radiation temperature and relative humidity sensors
Hygrothermometers are instruments for measuring air temperature and relative humidity.
Sensitive elements are protected from incident solar radiation by means of a set of anti-radiant devices. The first is a brass pipe through which air flow by means of either natural ventilation or forced ventilation of an aspirator; the second is a white, finned external aluminium shield. Versions C512TH, C312T, C512T are fitted with an aspirator for the forced ventilation of the sensitive elements. The temperature sensitive element is a Pt100, the humidity sensitive element is a capacitive plate. The sensor range included transducer with "normalised" and with "direct" outputs. In the case of versions C512TH, C512T, C502TH, C502T the transducer and connection cable must be included in the supply; version C312T and C302T already fitted with a standard 10 meter long cable.
Información en PDF (299 Kb.), humedad y temperatura
Información en PDF (654 Kb.), transmisión via radio con sensor de humedad y temperatura
Información en PDF (120 Kb.), conjunto medida humedad, temperatura y presión atmosferica

MODELS & CODES

   Description
Transducer Power Supply:
Outputs:
24Vca
4 .. 20 mA
24Vca
0 .. 20 mA
12Vcc
0 .. 5 V
12 Vcc
0 .. 300 mV
-
Pt100
C512T Temperature probe with forced ventilation and normalize output DMA528 DMA530 DMA550 - -
C502T Temperature probe with natural ventilation and normalize output DMA532 DMA534 DMA552 - -
C512TH Temperature and humidity probe with forced ventilation and normalize output. DMA529 DMA531 DMA551 - -
C502TH Temperature and humidity probe with natural ventilation and normalize output DMA553 DMA535 DMA553 - -
C312T Temperature probe with forced ventilation and direct output - - - - DMA028
C302T Temperature probe with natural ventilation and direct output. - - - - DMA033

THERMOHYGROMETERS TECNICAL CHARACTERISTICS

Characteristics C512TH C502TH
Temperature range -30.+70C -30.+70C
RH % range 0..100% 10..98% effective 0..100% 10..98% effective
Temperature element Pt100 1/3 Din Pt100 1/3 Din
RH% element Capacitive Capacitive
Temperature accuracy 0,2C 0,2C
RH% accuracy 3% 3%
Ventilation Forced Natural
Load resistance max 500 Ohm max 500 Ohm
Power consumption Max. 1,5 + 3,5 Watt Max. 1,5 Watt
Temperature limits -30.+70C -30.+70C
Protection against electric discharge "tranzorb" and "gas discharge" units "tranzorb" and "gas discharge" units
Material Aluminum protected with polyurethane paint Aluminum protected with polyurethane paint
Weight 4,6 Kg 1,7 Kg
Connection 7 pins connector, IP-65 protection 7 pins connector, IP-65 protection
Connection cable 6-wire+shield cable not included
L.= 10, 25, 50, 100 mt.
6-wire+shield cable not included
L.= 10, 25, 50, 100 mt.
Mounting by mean of DYA051 single collar on meteo pole 5 cm by mean of DYA051 single collar on meteo pole 5 cm

THERMOMETERS TECNICAL CHARACTERISTICS

Characteristics C512T C502T C312T C302T
Range -30.+70C -30.+70C -30.+70C -30.+70C
Element Pt100 1/3DIN Pt100 1/3DIN Pt100 1/3DIN Pt100 1/3DIN
Accuracy 0,2C 0,2C 0,1C 0,1C
Ventilation Forced Natural Forced Natural
Load resistance Max. 500 Ohm Max. 500 Ohm - -
Power consumption Max. 0,7+3,5 W 0,7 W Max. 3,5 W -
Temperature limits -30.+60C -30.+60C -30.+60C -30.+60C
Protection against electric discharge "tranzorb" and "gas discharge" units "tranzorb" and "gas discharge" units- - -
Material Aluminum protected with polyurethane paint Aluminum protected with polyurethane paint Aluminum protected with polyurethane paint Aluminum protected with polyurethane paint
Weight 4,4 Kg 1,5 Kg 3,4 Kg 2,5 Kg
Connection 7 pins connector, IP-65 protection 7 pins connector, IP-65 protection Terminals Terminals
Connection cable 6-wire+shield cable not included
L.= 10, 25, 50, 100 mt..
6-wire+shield cable not included
L.= 10, 25, 50, 100 mt.
Included
10 mt (opz. max 30 mt)
Included
10 mt (opz. max 30 mt)
Mounting by mean of DYA051 single collar on meteo pole 5 cm by mean of DYA051 single collar on meteo pole 5 cm by mean of DYA051 single collar on meteo pole 5 cm by mean of DYA051 single collar on meteo pole 5 cm

ACCESSORIES

Cod. Description
DWA510 Cable L = 10 mt with connector for series "500" sensors
DWA525 Cable L = 25 mt with connector for series "500" sensors
DWA526 Cable L = 50 mt with connector for series "500" sensors
DWA527 Cable L = 100 mt with connector for series "500" sensors
DYA051 Single collar for fitting sensors on meteo pole diam. 50 mm

MOUNTING: